Parameter setting dialogs of various FBs are available again in the FB-Editor (elimination)

Which products are affected?
In the FB-Editor parameter setting dialogs of the following FBs (library LenzeLineDrive) are available:
  • L_LdPosCtrlLin
  • L_LdClutchAxisP
  • L_LdClutchV
  • L_LdConvAxisV
  • L_LdExtrapolate
  • L_LdMPot
  • L_LdSetAxisVelocity
  • L_LdLinearCoupling
  • L_LdToolControl
  • L_LdVirtualMasterP
  • L_LdVirtualMasterV

Eliminated function restriction
In previous Engineer versions the surfaces of the parameter setting dialogs of function blocks selected by means of the FB-Editor sometimes showed incorrect codes or no codes at all. Therefore, these parameter setting dialogs were no longer displayed.  
With Engineer version 1.5 this function restriction is eliminated so that the above-mentioned FBs in the FB-Editor can now be operated by means of parameter setting dialogs.