Addition of virtual master functionality to function blocks

Functional description
Additions have been made to the L_LdVirtualMasterV and L_LdVirtualMasterP function blocks in respect of their input signals. Master speed 1 can now be defined via the dnSpeedSet_s process input.
In addition, a new input signal dwOperationMode allows operating mode preselection via a control input. In this case, the code for this operating mode preselection must be set to the new setting 3 = 'speed and mode via the input'.

Applications
Applications in which all operating modes of the virtual master are to be capable of being used without SDO access to the codes inside the function block
Applications in which the virtual master speed is available as a process datum (e.g. via a data bus system).

Contained in which products/versions?
LenzeLineDrive library V02.07.06.00 and higher, included from Engineer HighLevel 2.10 SP2 onwards

 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200910874/1/