Motor selection for i550 stops with error message (corrected from V1.13)

Corrected from:
EASY Starter V1.13
 
Response of the new version:
The function restriction has been solved. If the load moment of inertia is unknown at the time of selection of the motor, it is assumed to be 0 for the calculations taking place.
 
 
What happens?
Selecting a motor via the <Select Motor > button (motor from catalogue) on the 'Settings' tab, is terminated with the following message:
Parameter setting ended with errors

0x2910:002 Inertia settings: Load inertia  ? kg cm2

Error while reading parameter:  Value is not initialized.

 

When does this behaviour occur?
The above-described behaviour occurs when adding an i550 frequency inverter 'offline from package' in the EASY Starter and selecting and inserting a motor via the motor catalogue ('Settings' tab, <Select Motor> button).
 
Which products are affected?
EASY Starter from V1.12
 
Short-term measures:
Open the parameter list and enter the correct load moment of inertia for the parameter 0x2910:002. After this, use the <Select Motor> button and add the motor once again to the parameter set.
 
Evaluation/recommendations:
After adding the i550 frequency inverter via the 'Offline from Package' tab, the parameter 0x2910:002 is not initialised with a value. Therefore, parameter setting is aborted with errors when a motor is selected. 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201700317/1/