Automatic execution of 'Data Restore'

Function extension:
When restoring ('Restore' action) a backup, the controller checks if the firmware can be loaded from the backup into the controller. If this is not the case, only a 'Data Restore' will be executed. The 'Data Restore' action can no longer be manually selected in the 'Backup&Restore' software.

With 'Data Restore', only the project data of an existing backup (PLC project, VisiWinNET project, settings,...) will be restored on the controller. The firmware version of the controller stored in the backup will not be restored. 'Data Restore' thus corresponds to replacing the SD card when replacing controllers.

Contained in which products?
Backup&Restore V3.16

c300 controller V3.16
3200C controller V3.16
p300 panel controller V3.16
p500 panel controller V3.16

Application:

Due to hardware adjustments in the controllers, you can no longer load any firmware into any controller.