TA SyncAndCorrection: Some errors are not reported (corrected from V01.02.03)

Eliminated from:
TA_i900:    from V01.02.03.0985
 
Behaviour of new version:
In the event of an error, the corresponding error codes are now displayed in parameter 0x5040:114 (Error code).

 
What happens?
Although an error is pending, the technology application reports no error in parameter 0x5040:114 (error code).
 
When does this behaviour occur?
The behaviour occurs when using the technology application and one of the following errors occurs:
Error number (L_IE1P)Error textError cause
​17000​ModuloAxisIsRequiredInstead of a Modulo axis, a linear axis is connected.
​17006​MarkStackLimitReachedThe length of the stacks for the end marks has been exceeded as the distance between touch probe sensor and tool is bigger than the length of the register.
​17110​MasterIsReversingThe master axis changes the direction of rotation.
​17117​CorrectionGreaterCorrWindowThe correction value is greater than the available correction window.
​17170​SyncModeVelAccRequiredSynchronisation to the master axis requires the "Ramp_VelAcc" coupling mode.
​17177​lrMarkDist <= 0 The parameterised mark distance is not permissible. A value <= 0 has been set.
​19503​MaxNrOfTpExceeded_MarkRegisterThe mark stack has exceeded the maximum number of permissible marks.
​20664​Invalid_GearFactorInvalid gearbox factor
​20667​PosInInvalid_AddOffsetCyclicInvalid input position AddOffsetCyclic
 
 
Which products are affected?
TA_i900:

Short-term measures, Evaluation/Recommendations:
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201800218/1/