Touchprobe configuration 1 and 2 - Behaviour with same source selection (fixed from V01.03.07)

Fixed:
Servo-Inverter i950 from V01.03.07    
 
Behaviour of the new version:
If both sensors are set to the same TP input channel, the user receives the error "TpAlredayInUse".
If one of the two sensors is now set to a different input channel, there is no more error.
 
 
Description of the Behaviour:
Touchprobe is not triggered.
No error or warning is triggered.
 
Under what conditions does the behaviour occur?
Both touch probes are set to the same input channel.
Example:
  • Set TP Configuration 1 (0x5020:11) to DigIn1_PosEdge (default)
  • Set TP Configuration 2 (0x5020:12) to DigIn1_PosEdge
Affected products:
Servo-Inverter i950
 