Fieldbus interface variables not correctly mapped in the technology application (fixed from V01.03.07)

Fixed:
Servo-Inverter i950 (from V01.03.07)
Behaviour of the new version:
The fieldbus variables are correctly mapped to the variables of the technology application (TA).
Description of the behaviour:
ElectronicGearbox:  The two status signals 3 and 7 are reversed.
WinderTension: Control word 2 is copied to control word 1. The diameter cannot therefore be preloaded via the fieldbus.
Under what conditions does the behaviour occur?
The signals described above are used.
Affected products:
Servo-Inverter i950 withTA ElectronicGearbox or TA WinderTension
Short-term measures:
Winder Tension: Preloading the diameter via the parameter 0x5051:066 (Start diameter set Value)
ElectronicGearbox: no short-term measures
 