i950 TA Winder: Adaptation of speed amplification does not work (fixed from V03.20.00; V01.04.01)

Corrected from:
Library: L_TW2P_TechModulesWindingTraversing (from V03.20.00.33)
Servo inverter i950 with TA Winder (from FW V01.04.01)
 
Response of the new version:
The maximum value of the adaptation for the speed amplification is limited to 100%.
 
 
What happens?
Function module L_TW2P_WinderTension/DancerCtrlState:
Values for the adaptation of the speed amplification > 100% are calculated. The speed control does not function correctly.
 
When does the behaviour occur?
The function "Enable speed controller adaptation" (CtrlWord bit 29) is used.
 
Which products are affected:
Library: L_TW2P_TechModulesWindingTraversing
Servo inverter i950 with TA Winder
  
Short-term measures:
By deactivating the function "Enable speed controller adjustment" (CtrlWord bit 29) depending on the diameter, 100% is set for the adaptation of the speed amplification.
  
Evaluation / Recommendations:
Taking into account the short-term measure, the function of speed amplification adaptation can be used.
 
Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201900293/1/
Contact form