i950 TM and TA ElectronicGearbox: status signal toggles (fixed from V0.20.0; V01.04.01

Corrected from:
Library: L_TS2P_TechModulesSynchronizingCamming (from V03.20.00.60)
i950 Servo inverter with TA ElectronicGearbox (from V01.04.01)

Response of the new version:
The status signal 0x5040:110 Bit 10 does not toggle in the coupled state at constant speed.
 
What happens?
Function module L_TS2P_ElectronicGearbox from
After coupling, the status signal also toggles at constant speed.
 
When does the behavior occur?
The status signal scStatusBasicMotion.xConstantVelocity is used.
Or the status bit 10 (0x5040:110; Target Velocity Reached) is used.
 
Which products are affected?
Library: L_TS2P_TechModulesSynchronizingCamming
i950 Servo inverter with TA ElectronicGearbox
 