i950 with TA ElectronicGearbox, SyncAndCorrection: Clock operation is executed despite stop (fixed from V01.04.01)

Corrected from:
TA i900 (i950 servo inverter):  corrected from FW V01.04.01
(Update via Easy Package Manager)
 
Response of the new version:
After the error reset, a stop is executed with a request for a STOP and no cycle operation.

 
What happens?
TA ElectronicGearbox [40] and TA SyncAndCorrection [41]:
The cyclic operation (CyclicMotion) is still executed.
 
When does the behaviour occur?
- CyclicMotion with SetVel = 0
- CyclicMotion = FALSE
- error reset
- Enter SetVel > 0, stop= TRUE
 
Which products are affected?
TA i900 (i950 servo inverter)
 
Short-term measures / Evaluation/Recommendations:
 