TA Sync And Correction: Offset is not switched through/extended (eliminated from V03.20.00; V01.04.01)

Corrected from:
Library:  L_TS2P_TechModulesSynchronizingCamming  from V03.20.00.60
TA i900 (i950 Servo inverter)  from V01.04.01.xx
(Update via Easy Package Manager)
 
Response of the new version:
The set offset and trim value is extended and effective in the total conductance.
 
 
What happens:
TA Sync And Correction (0x4000:0 = [41]):
Function block L_TS2P_SyncAndCorrectionState:
A set offset and/or trim value is no longer extended/switched through.
 
When does the behaviour occur?
Set the master axis and slave axis to Limited.
 
Which products are affected?
Library:  L_TS2P_TechModulesSynchronizingCamming
TA i900 (i950 Servo inverter)
 