Corrected from:
EASY Starter V1.21
Response of the new version:
The timeout time for uploading the complete device application from a Servo Inverter i950 has been extended. This means that a timeout error message no longer occurs.
What happens?
When uploading the complete device application from an i950 Servo Inverter the error message appears:
I2022Command 42 failed: Timeout
When does the behaviour occur?
If an application is executed in the i950 Servo Inverter that requires a lot of computing power, then the i950 is not able to provide the EASY Starter with the file containing the device application in time. The timeout error message described above occurs.
Which products are affected?
EASY Starter fromV1.13
Short-term measures:
Before uploading the device application, stop processing the application in the i950 servo inverter.
Evaluation/Recommendations:
If the i950 Servo Inverter is heavily loaded due to the running application, it is not possible to upload the device application during runtime.
Automatic Translation