i950 TA SyncAndCorrection: No correction via correction window (corrected from V1.8)

Corrected from:
Servo inverter i950 with TA SyncAndCorrection (from FW 1.8.0)
(Update via Easy Package Manager)

Response of the new version:
To be able to correct the behaviour over the entire range of the mark distance can be activated via the correction mode "Profile generator".
The activation is done in the TA SyncAndCorrection via the parameter: 0x5041:59 (Markcorrection mode) = 1.
The desired parameters for speed, acceleration, deceleration and jerk of the correction are made via the parameters

0x5041:60 (Markcorrection velocity)
0x5041:61 (Mark Correction acceleration)
0x5041:62 (Markcorrection deceleration)
0x5041:63 (Markcorrection jerk)

The same procedure can be selected for the tool offset.
Here the parameterisation is done via the following parameters:

0x5041:131 (Toolcorrection mode)
0x5041:132 (Toolcorrection velocity)
0x5041:133 (Toolcorrection acceleration)
0x5041:134 (Toolcorrection deceleration)
0x5041:135 (Toolcorrection jerk)

With this type of correction, the correction window has no effect. The duration and location of the correction depend only on the profile parameters used.
The correction starts immediately after the mark is recognised.
 
What happens?
If the entire range of the mark distance is parameterized as a correction range, no correction takes place.

When does the behaviour occur?
For mark corerction:
 0x5041:007 (Lower correction position) = 0
 0x5041:006 (Upper correction position) =  0x5041:002 (Mark distance)
 
For tool compensation:
 0x5041:125 (Lower correction position tool) = 0
 0x5041:124 (Upper correction position tool) =  0x500A:031 (Cycle length)

Which products are affected?
i950 servo inverter with TA SyncAndCorrection
 
Short-term measures:
Set upper correction position < 0x5041:002 (Mark distance)

Automatic Translation 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202000059/1/
Contact form