TA ElectronicGearbox / SyncAndCorrection: NoSetValuesAvailable (eliminated from V1.5.2)

Eliminated from:
Servo-Inverter i950 FW V01.05.02.1788
(Update via EASY Package-Manager)

Behaviour of new version:
The error message "NoSetValuesAvailable" no longer appears.

What happens?
- When disengaging the Virtual Master, the error message "NoSetValuesAvailable" is displayed.

When does the behaviour occur?
-    Axis 1 is the master for axis 2 (setpoints with disabled controller or actual values are sent via the system bus)
-    Axis 2 has the system bus as its conductance source and the Virtual Master couples
-    If axis 2 is now decoupled (0x5045:011 = 0) via the control word 0x5040:010 bit 31 (deactivate external reference values), the error "NoSetValuesAvailable" will occur earlier or later

Which products are affected?
i950 BS/ES with the TA Electronic Gearbox (0x4000:0 = [40])
i950 BS/ES with the TA Sync And Correction (0x4000:0 = [41])

Short-term measures:
0x5045:011 with a value > 0 vorgeben.

Evaluation/Recommendations: