Corrected from:
i950 Servo-Umrichter (from FW V01.06.4)
Behaviour of new version:
The error "NoSetValues" does not occur after disengagement.
What happens?The axis of the virtual master reports the error "NoSetValues" during disengagement and goes to the error FailQSP.
When does the behaviour occur?
The behavior can occur if the conductance is an actual value-based conductance.
At the time of the disengagement request, the conductivity is in standstill, the target velocity of the virtual master 0x5045:011 is parameterized with 0 units/s.
Which products are affected?
i950 Servo Inverter with TA ElectronicGearbox
i950 servo inverter with TA SyncAndCorrection
Short-term measures
Set parameter 0x5045:011 <> 0
Automatic Translation