i950 TA Winder Tension: Status bit 0x5050:110 Bit 18 TensionCtrl =TRUE also at controller inhibit and error (corrected from V01.06.04)

Corrected from:
TA i900  from V01.06.04.2154

Behaviour of the new version:
TA winder tension:
Now 0x5050:110 Bit 18 is an image of the "xWindingBusy" output of the technology module.


What happens?
TA winder tension:
The status bit 0x5050:110 bit 18 (Tension Control Active) is apparently always TRUE if bit 18 (Enable Tension Control) in the control word 0x5050:10 is set. Especially also at controller inhibit or in ERROR or STANDBY states (see 0x5051:001).

When does the behaviour occur?
Bit 18 (Enable Tension Control) in the control word 0x5050:10 is TRUE.

Which products are affected?
i950 servo inverter with TA Winder. 

Short-term measures:
-