i950 TA TablePos: Unexpected error 0x2C0050B9 when switching between mode 'CW_modulo' and 'CCW_modulo'.

Corrected from:

Servo inverter i950 with TA TablePositioning (from V01.08.xx; in planning)
(Update via EASY Package Manager)

Response of the new version:

No error message is output. The positioning to the selected target position is carried out.

 
What happens?

An error is reported: '0x2C0050B9 Position outside the cycle length'. No positioning is executed.

 
When does the behaviour occur?

The positioning mode 'Absolute_CWW_modulo' is selected and a positioning to a target position greater than or equal to the cycle length is started.

 
Which products are affected?
Servoinverter i950 mit TA TablePositioning (0x4000 = TA TablePositioning [20])

Short-term measures:
Setting the target position in the negative range.

Ex: bar length is 360, target position is 360.
-> Default target position -360.

Evaluation / recommendations:
-

Automatic Translation


URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202100355/1/