Corrected from:
Servo inverter i950 with TA TablePositioning (from V01.08.00)
(Update via EASY Package Manager)
Response of the new version:
If an aborted positioning is completed (Finish Positioning), the status information "Positioning Profile Active" (bit 20) and "Positioning Profile Completed" (bit 21) are correctly displayed.
What happens?
If an aborted positioning is completed (Finish Positioning), the status information "Positioning Profile Active" (bit 20) and "Positioning Profile Completed" (bit 21) are missing.
When does the behaviour occur?
A positioning was interrupted by controller inhibit (bit 03 = FALSE) and is to be continued via bit 22 (continue positioning).
Which products are affected?
Servoinverter i950 mit TA TablePositioning (0x4000 = TA TablePositioning [20])
Short-term measures:
Cancel positioning via Abort and then lock the controller.
Evaluation / recommendations:
-