i950 TA Speed Control: PID control implemented

Function extension:
A PID controller was added to the TA signal flow.
This makes it possible to implement a closed-loop control structure whose controlled system lies directly in the process.

Typical applications:
  • Web tension control (process variable: tractive force)
  • Simple dancer position control (process variable: dancer position)
  • Pressure control for a hydraulic unit (process variable: pressure)
The actual values of the process variables are often fed back via the analogue input or the fieldbus interface.