TA Electronic Gearbox: The 10th system bus participant does not receive any process data (fixed from V1.9.1)

Fixed from:
Servo inverter i950 (from V01.09.01)

Behavior of the new version:
All system bus slaves receive the same setpoints via the system bus.


Description of the behavior:

In a topology with more than 9 system bus devices, the 10th device does not receive any master values (cycle length, position, speed, acceleration) via the system bus.

Affected products:
Servo Inverter i950


Short-term measure, recommendations, evaluation:
 -





Lifted from:
i950 Firmware V1.9.1.


Behavior of the new version:
All system bus slaves receive the same set values via the system bus.


Description of behavior:
 

Conditions under which the behavior occurs:

  • In a topology with more than 9 system bus nodes, the 10th node does not receive any control values (clock length, clock rate, etc.). In a topology with more than 9 system bus participants, the 10th participant does not receive any control values (cycle length, position, speed, acceleration) via the system bus.

 
Affected products:

i950 firmware <V1.9.1


Short-term measures, Recommendations, Rating:

-



[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202300436/1/