Design Time - Project Settings Editor: After saving changes, the project no longer starts.

Corrected from:
EASY UI Designer V1.5
Behavior of the new version:
The changes made in the "Project Settings Editor" are applied correctly and the project can be started.


Description of the behavior:

A project starts with the error message ".... Socket error".

 

Conditions under which the behavior occurs:

  • A change has been made in the "Project Settings Editor".
  • The "Project Settings Editor" was opened and closed again without any changes.
Affected products:

EASY UI Designer V1.4


Short-term measures, Recommendations, Rating:

In the "Project" menu of the EASY UI Designer, change the execution target once to "Local" and then back to "Target device".



[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202300520/1/
Contact form