EASY Starter displays the wrong signal flow depending on the operating mode

Corrected from:
EASY Starter V1.25.1
Behavior of the new version:
On the "Settings" tab in the "Overview" dialog, the "Signal flow" panel displays the signal flow that matches the set "Operating mode" (0x6060:000).


Description of the behaviour:
On the "Settings" tab in the "Overview" dialog, the "Signal flow" panel does not display the signal flow that matches the set "Operating mode" (0x6060:000).

The signal flow displayed for the operating mode "MS: Velocity mode [-2]" belongs to the operating mode "MS: Torque mode [-1]" and vice versa.


Conditions under which the behavior occurs:
Occurs online and offline.

Affected products:
EASY Starter from V1.25
All inverters i4xx, i5xx, i6xx
Short-term measures, Recommendations, Rating:
Use the EASY Starter V1.24.


[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202400009/1/