Multiple parameter sets for one EtherCAT device

Function extension:

For the following Lenze inverters, up to 5 different parameter sets can be created in the PLC Designer and downloaded to the Lenze Controller c430, c520 or c550:

  • i550 from V6.5
  • i700 from V2.16
  • i750 from V1.2
  • i950 from V1.10
The selection of which parameter set is loaded from the controller into the corresponding inverter can be defined both in the PLC Designer project and in the PLC logic of the controller:
PLC Designer_ParameterSetConfiguration_SSHOT.png

In the online case, the parameter set currently loaded in the controller is always displayed here. Online changes are then also saved in the inverter and in the parameter set in the PLC Designer project.

PLC Designer_ActiveParameterSet_SSHOT.png

The active parameter is exported using EASY Export. When saving the controller's parameter set in a fail-safe manner, the controller uploads the parameter sets of the connected drive controllers and saves them in the active parameter set in the controller.

Contained in the following products:

PLC Designer V4.0 

Application:

If, for example, different motors are connected to the same drive in a series machine, the resulting different parameter sets can be stored in the PLC Designer project and the controller can load the appropriate one into the inverter.