Question: What causes can a CE04 MCI communication error have?
Answer: If MCI is set as source for synchronization in C1120/0 [4], the synchronization signal is expected at a specified time. The code position C01123/0 defines a time window around the synchronization time in which the sync signal must arrive. This time window must be set to 100µs. A different setting can lead to CE04 error messages.
Further possible causes are: - EMC faults - Communication module not inserted correctly - Defect of the communication module or the drive controller
Taxonomy:
8400 TopLine frequency inverters
,
8400 HighLine frequency inverters
,
8400 StateLine frequency inverters
AKB-ID:
201900250
Last update:
2024/01/11
Category:
Foire aux questions (FAQ), conseils et astuces