Combination of 9400 drive controller with 9300 brake chopper

Question:
Can 935x brake choppers be operated in a DC-bus connection with 9400 drive controllers?

Answer:
Yes, a combination 935x with the following devices is possible:

9400 Multi Drives:
all

 Supply modules:
 all

 9400 SingelDrive:
 E94ASxE0324   15 kW
 E94ASxE0474   22 kW
 E94ASxE0594   30 kW
 E94ASxE0864   45 kW
 E94ASxE1044   55 kW

 

 The 935x brake modules are not allowed to be combined with the following SingleDrive devices.

 9400 Single Drives:
 E94ASxE0024   0.37 kW
 E94ASxE0034   0.75 kW
 E94ASxE0044   1.5 kW
 E94ASxE0074   3.0 kW
 E94ASxE0134   5.5 kW
 E94ASxE0174   7.5 kW
 E94ASxE0244   11 kW
 
 E94ASxE1454   75 kW
 E94ASxE1724   90 kW
 E94ASxE2024   105 kW
 E94ASxE2454   130 kW
 E94ASxE2924   150 kW
 E94ASxE3664   190 kW
 E94ASxE4604   240 kW
 E94ASxE5724   300 kW
 E94ASxE6354   335 kW
 E94ASxE6954   370 kW
 
E94BSxE1454   75 kW
 E94BSxE1724   90 kW
 E94BSxE2024   105 kW
 E94BSxE2454   130 kW
 E94BSxE2924   150 kW
 E94BSxE3664   190 kW
 E94BSxE4604   240 kW



Note:
If one of the mentioned 9400 Single Drives is integrated in the DC-bus connection, it is not allowed to connect any 935x brake module to the CD-bus connection.
The mentioned devices contain current-compensated chokes in the DC-bus, which are able to trigger a 935x brake chopper to start a sympathetic oscillation, so that it can change over to a continuous chopper operation.

 

The following technical combinations are possible:

__________________________________________________________________________________
935x brake chopper       |    9400 supplier    _     |    9400 device size 1-3 and 8-10       |    9400 device size 6-7
                X                  _ |          __   X                  |                       ___  O                           |                  X                ___
                O              __   |             __X                  |                          ___X                           |                  X                ___

- Several brake choppers of one type are allowed to be integrated in the DC-bus connection.


X = brake chopper in the DC-bus  
O = no brake chopper in the DC-bus

For synchronisation please consider:
935x brake choppers with 9400 supplier are to be synchronised.
935x brake choppers with 9400 axes, device size 6-7 cannot be synchronised.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200704931/1/