i950 ES: With permanent PDSS activation, the currently monitored speed (0x28DE:012) is not displayed (corrected from V01.03.05)

Fixed from:
i950 Extended Safety from V01.03.05.00

Behavior of the new version:
Now the display of the current speed (0x28DE:012) is always displayed when the PDSS function is active, regardless of the selection in object 0x28DE:001.


Description of behavior:
While using PDSS, the currently monitored speed (0x28DE:012) is not displayed.

Under which conditions does the behavior occur?
The value of the monitored speed (0x28DE:012) remains at 0 rpm if the value " Activated " has been selected for PDSS: Permanent activation 0x28DE:001.
If the value "On demand" is selected for PDSS: Permanent activation 0x28DE:001, the correct value is displayed in 0x28DE:012.

Affected products:
i950 Extended Safety
 
Evaluation/Recommendations: 
The current PDSS speed value is correctly calculated and monitored at all times. 
The function restriction is only a display error that has no influence on the PDSS safety function.
If the display in 0x28DE:012 is to be used, activation must be via S-Bus or a digital input.



URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202100340/1/