i950 ES: With permanent PDSS activation, the currently monitored speed (0x28DE:012) is not displayed (corrected from V01.03.05)
Fixed from:
i950 Extended Safety from V01.03.05.00
Behavior of the new version:
Now the display of the current speed (0x28DE:012) is always displayed when the PDSS function is active, regardless of the selection in object 0x28DE:001.
Description of behavior:
While using PDSS, the currently monitored speed (0x28DE:012) is not displayed.
Under which conditions does the behavior occur?
The value of the monitored speed (0x28DE:012) remains at 0 rpm if the value " Activated " has been selected for PDSS: Permanent activation 0x28DE:001.
If the value "On demand" is selected for PDSS: Permanent activation 0x28DE:001, the correct value is displayed in 0x28DE:012.
Affected products:
i950 Extended Safety
Evaluation/Recommendations:
The current PDSS speed value is correctly calculated and monitored at all times.
The function restriction is only a display error that has no influence on the PDSS safety function.
If the display in 0x28DE:012 is to be used, activation must be via S-Bus or a digital input.